    General

    User Interface Languages

    English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian, Italian
    Transducer Connections LEMO 00
    Data Storage 100,000 IDs onboard
    Battery Type and Life Single lithium-ion rechargeable standard; 6 h life
    Power Requirements AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 Hz to 60 Hz
    Display Type Full VGA (640 ¡¿ 480 pixels) transflective color LCD, 60 Hz update rate
    Display Dimensions (W ¡¿ H, Diag.) 117 mm ¡¿ 89 mm, 146 mm (4.62 in. ¡¿ 3.49 in., 5.76 in.)
    Overall Dimensions (W ¡¿ H ¡¿ D) 209 mm x 128 mm x 36 mm, 58 mm at hand grip (8.2 in. x 5 in. x 1.4 in., 2.3 in. at hand grip)
    Weight 890 g (1.95 lb), including lithium-ion battery
     

    Instrument Inputs/Outputs

    USB Ports (1) USB 1.1 Full Speed Host (Type A)
    (1) USB 2.0 Full Speed Client (Type Mini B)
    Video Output 1 digital video output
     

    Environmental Ratings

    IP Rating Ingress Protection (IP) engineered to IP67 (dust tight and water submersion) and IP65 (dust tight and water jets) per IEC 60529-2004 (Degrees of Protection provided by enclosures—IP Code). The product rating is confirmed by means of Olympus' internal design verification test process.
    Explosive Atmosphere MIL-STD-810F, Method 511.4, Procedure 1.
    Shock Tested MIL-STD-810F, Method 516.5, Procedure I, 6 cycles each axis, 15 g, 11 ms half sine.
    Vibration Tested MIL-STD-810F, Method 514.5, Procedure I, Annex C, Figure 6, general exposure: 1 hour each axis.
    Operating Temperature -10 ¡ÆC to 50 ¡ÆC (14 ¡ÆF to 122 ¡ÆF)
    Battery Storage Temperature 0 ¡ÆC to 50 ¡ÆC (32 ¡ÆF to 122 ¡ÆF)
     

    Pulser

    Pulser Turnable square wave
    PRF 10 Hz to 2000 Hz in 10 Hz increments
    Energy Settings 100 V, 200 V, 300 V, or 400 V
    Pulse Width Adjustable from 25 nsec to 5,000 nsec (0.1 MHz) with PerfectSquare¢â technology
    Damping 50, 400 ¥Ø

    Receiver

    Maximum Input Signal 20 Vp
    Receiver Input Impedance 400 ¥Ø ¡¾ 5%
    Receiver Bandwidth DC to 26.5 MHz at -3 dB (standard version)
    0.2 to 26.5 MHz at -3 dB (ISO 22232-1:2020 compliant version)
    Digital Filter Settings 8 digital filter sets (standard version)
    7 digital filter sets (ISO 22232-1:2020 compliant version)
    Rectification Full-Wave, Positive Half-Wave, Negative Half-Wave, RF
    System Linearity Horizontal: ¡¾ 0.5% FSW
    Resolution 0.25% FSH, Amplifier Accuracy +/- 1dB
    Reject 0 to 85% FSH in 1% increment positions
    Amplitude Measurement 1.25% to 110% full screen height
    Measurement Rate Equivalent to PRF in all modes (single shot)
     

    Calibration

    Automated Calibration Velocity, zero offset
    Straight beam (first back wall or echo-to-echo)
    Angle beam (sound path or depth)
    Test Modes Pulse Echo, Dual, or Through Transmission
    Units Millimeters, inches, or microseconds
    Range 4.31 mm to 6,700 mm at 5,900 m/s (0.2320 in./¥ìs)
    Velocity 635 m/s to 15240 m/s (0.0250 in./¥ìs to 0.6000 in./¥ìs)
    Zero Offset 0 to 750 ¥ìs
    Display Delay -10 microseconds to 2203 microseconds
    Refracted Angle 0¡Æ to 85¡Æ in 0.1¡Æ increments, then jump to 90¡Æ
     

    Gates

    Measurement Gates 2 fully independent flaw gates
    Gate Start Variable over entire displayed range
    Gate Width Variable over entire displayed range
    Gate Height Variable from 2 to 95% full screen height in 1% increments
    Alarms Positive and negative threshold/curve, minimum depth (gate 1 and gate 2)
     

    Measurements

    Measurement Display Locations 5 locations available (manual or auto selection)
    GATE (1, 2) Thickness, sound path, projection, depth, amplitude, time-of-flight, min./max. depth, min./max. amplitude, sizing measurements based on mode
    Measurement Display Locations User selects up to four measurements from either gate to display on the live screen.
    Echo-to-echo Standard gate 2 – gate 1
    DAC/TCG Standard, up to 50 points, 110 dB dynamic TCG range
    Special DAC Modes Custom DAC (up to 6 curves), 20–80% view
    Curved Surface Correction Standard OD or bar correction for angle beam measurements

     

    * °è»ê¼­ ¹ßÇà ¿äû½Ã ¹ßÇà °¡´ÉÇÕ´Ï´Ù . (Ä«µå ±¸ÀԽà Á¦¿Ü ) * ¹«´Ü º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í ÃÊÀ½ÆÄ °áÇÔ °ËÃâ±â, EPOCH 6LT
    ÆǸŰ¡°Ý 4,567¿ø
    ºê·£µå olympus
    ¿ø»êÁö ÀϺ»
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : ¿¡À̺ñÅ¥     ÁÖ¼Ò : ÀÎõ °è¾ç±¸ ÀÛÀüµ¿ 859-11     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2022-ÀÎõ°è¾ç-1264È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ :      °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü : µðÁöÀ¥